您好, 歡迎來到化工儀器網(wǎng)! 登錄| 免費(fèi)注冊(cè)| 產(chǎn)品展廳| 收藏商鋪|
當(dāng)前位置:上海境宣實(shí)業(yè)有限公司>>日本光明北川式氣體檢測(cè)管>>氣體快速檢測(cè)管>> 171SC甲醛HCHO氣體測(cè)毒管171SC FORMALDEHYDE 0.05-4.0ppm
參 考 價(jià) | 面議 |
產(chǎn)品型號(hào)171SC
品 牌
廠商性質(zhì)代理商
所 在 地上海市
更新時(shí)間:2025-05-12 18:42:35瀏覽次數(shù):1830次
聯(lián)系我時(shí),請(qǐng)告知來自 化工儀器網(wǎng)苯氣體檢測(cè)管118SB BENZENE 5-300ppm
室內(nèi)空氣甲醛檢測(cè)管No.713 FORMALDEHYDE 0.01-0
氯乙烯CH2=CHCl氣體測(cè)毒管132SC VINYL CHLORID
氯乙烯CH2=CHCl氣體檢知管132SB VINYL CHLORID
甲醛HCHO氣體測(cè)毒管171SC FORMALDEHYDE 0.05-4.0ppm
Tube 71SC
1. PERFORMANCE
1) Measuring range :0.1-4.0 ppm 0.05-2.0 ppm
Number of pump strokes 5(500mr) 10(1000ml)
2) Sampling time :5 minutes/5 pump strokes
3) Detectable limit :0.03 ppm(1000ml)
4) Shelf life :1 year (Necessary to store in a refrigerated place ; 0~10℃)
5) Operating temperature :10~40℃
6) Temperature compensation :Necessary(See "TEMPERATURE CORRECTION TABLE")
7) Reading :Direct reading from the scale calibrated by 5 pump strokes
8) Colour change :Yellow→Pink
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:10% RSD-high:10%
3. CHEMICAL REACTION
By reaction with Hydroxylamine phosphate acid is liberated and PH indicator is discoloured.
HCHO+(NH3OH)3?H3PO4→H3PO4+HCH=NOH+H2O
4. CALIBRATION OF THE TUBE
COLOURIMETRY METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
GAS To pump
4.0
3.0
2.0
1.0
0.1
0.5
0.3
500ml
ppm
(White)
DEHUMIDIFIER
171SC FORMALDEHYDE
Substance ppm Interference ppm Coexistence
Ammonia
The accuracy of readings is 10 Lower readings are given. Inlet
not affected. side is faded the discoloured layer.
Higher readings are given. The
Nitrogen dioxide 3 Similar stain is produced. 3 top of discoloured layer becomes
unclear.
Acetaldehyde 〃Higher readings are given.
Toluene
The accuracy of readings is
not affected.
TEMPERATURE CORRECTION TABLE
Tube Corrected Concentration (ppm)
Readings 10℃ 20℃ 30℃ 40℃
(ppm) (50°F) (68°F) (86°F) (104°F)
4.0 6.4 4.0 2.4 1.6
3.5 5.6 3.5 2.1 1.4
3.0 4.8 3.0 1.8 1.2
2.5 4.0 2.5 1.5 1.0
2.0 3.2 2.0 1.2 0.8
1.5 2.4 1.5 0.9 0.6
1.0 1.6 1.0 0.6 0.4
0.5 0.8 0.5 0.3 0.2
0.3 0.5 0.3 0.18 0.12
0.1 0.16 0.1 0.06 0.04
(NOTE)
In case of 10 pump strokes, following formula is available for the actual concentration.
Actual concentration = 1/2 × Tmperature corrected value